MobileIron Sentry: Exchange 2003 (http 500 error)


When using standalone Sentry in an MobileIron environment with Exhcange 2003 and you see html 500-error-codes in the log of the Sentry-appliance have a look at your Exchange-server and double check that 'formular-based authentication' is disabled!

If enabled MobileIron Sentry cannot access the Exchange 2003 server